1-4
SUPERSERVER 1012G-MTF User's Manual
Figure 1-1. AMD SR5690/SP5100 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Cooling System
The SC813MTS-350C chassis has an innovative cooling design that features four
4-cm high-performance system cooling fans. Each of these fans plug into a chassis
fan header on the motherboard. An air shroud channels the airfl ow generated by
the fans to effi ciently cool the processor area of the system.
A fan speed control setting in BIOS allows fan speed to be determined by system
temperature [the recommended setting is Balanced].
DIMM A0
DIMM A1
CPU1
HT3 Link
16/16-3.2GHz
DIMM B0
DIMM B1
DIMM C0
DIMM C1
DIMM D0
DIMM D1
PCI SLOT1
PCI-E GEN2 X8
Slot6 PCIE x8/x16
IDE (ATA/133)
SA
TA x6
PCI-E GEN2 X8
Slot5 x8
PCI-E GEN2 x1
INTEL
82574L
RJ45
A-Link
SP5100
BMC
VGA
WPCM450-R
PCI
LPC
SMBus
SIO
W83527HG
HWM
W83795G
SPI Flash
KB/MS
COM2
RMII
DDR2 SDRAM
64MB X16
PSU I2C
IPMB
FE PHY
RTL8201N
VGA
RJ45
Clock Gen
TPM
SR5650
COM1
RJ45
INTEL
82574L
PCI SLOT2
PCI SLOT3
PCI-E GEN2 X4
Slot4
SWITCH
PCI-E GEN2 x1
8xUSB
Comentários a estes Manuais