Supermicro SYS-7046GT-TRF Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Servidor barebones Supermicro SYS-7046GT-TRF. Supermicro SYS-7046GT-TRF server barebone Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 120
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1

SUPERSUPERSERVER 7046GT-TRF 7046GT-TRF-TC4®USER’S MANUALRevision 1.0

Página 2

1-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 7046GT-TRF/7046GT-TRF-TC4 lies the

Página 3 - Manual Organization

7-18SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualThe options are:The Early Alarm: Select this setting if you want the CPU overheat alarm (i

Página 4

Chapter 7: BIOS7-19User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.High – T

Página 5

7-20SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualXACPI Confi gurationUse this feature to confi gure Advanced Confi guration and Power Interfac

Página 6 - Table of Contents

Chapter 7: BIOS7-21ACPI Version FeaturesThe options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanatio

Página 7 - Chapter 4 System Safety

7-22SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualXIPMI Confi gurationIntelligent Platform Management Interface (IPMI) is a set of common int

Página 8

Chapter 7: BIOS7-23Clear BMC System Event LogClear BMC System LogSelect OK and press the <Enter> key to clear the BMC system log. Select Cancel

Página 9 - Introduction

7-24SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualSubnet MaskThis item displays the current subnet mask setting for your IPMI connection.Cur

Página 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-25XEvent Log Confi gurationView Event LogUse this option to view the System Event Log.Mark all events as readThis option marks all eve

Página 11 - 1-3 Server Chassis Features

7-26SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the

Página 12 - Backplane

Chapter 7: BIOS7-277-5 Boot Confi gurationUse this feature to confi gure boot priority settings. XBoot Device PriorityUse this feature to specify the se

Página 13 - System Block Diagram

1-3Chapter 1: IntroductionOnboard Controllers/PortsThe color-coded I/O ports include one COM port (an additional COM header is located on the serverbo

Página 14 - 1-5 Contacting Supermicro

7-28SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Ex

Página 15 - System Setup

Chapter 7: BIOS7-29Load Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Saf

Página 16 - 2-3 Setting Up the System

7-30SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualNotes

Página 17 - Choosing a Setup Location

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Página 18 - Warnings and Precautions!

A-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualNotes

Página 19 - Rack Mounting Considerations

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Página 20

B-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualB-2 Installing Windows for a Non-RAID SystemInsert Microsoft's Windows XP/Windows 200

Página 21

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsTwo Intel 5500 Series (LGA 1366) processorsNote: Please refer to our web

Página 22

C-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualExpansion SlotsFour PCI-E Gen. 2.0 x16 slots (Slot 4, Slot 6, Slot 8, Slot 10)• One PCI-E G

Página 23

C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A

Página 24

1-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualHard Drive/Drive BaysThe SC747 Chassis features eight slots for SAS/SATA drives. These driv

Página 25 - Installing the Chassis Cover

C-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be

Página 26

1-5Chapter 1: IntroductionFigure 1-1. Intel 5520 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for details.

Página 27 - System Interface

1-6SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San J

Página 28 - 3-3 Control Panel LEDs

Chapter 2: Server Installation2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7046GT-TRF/70

Página 29

2-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual2-3 Setting Up the SystemYou should fi rst open the left side panel (when facing the front

Página 30 - 3-4 Drive Carrier LEDs

Chapter 2: Server Installation2-3Check the SATA disk drives: Depending upon your system's confi guration, 2. your system may have up to four SATA

Página 31 - System Safety

2-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualRack PrecautionsEnsure that the leveling jacks on the bottom of the rack are fully extended

Página 32

Chapter 2: Server Installation2-5Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Página 33 - 4-3 ESD Precautions

Manual Revision 1.0 Release Date: October 25, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accur

Página 34 - BATTERY HOLDER

2-6SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual2-5 Installing the Chassis onto a RackThis section provides information on installing the

Página 35 - Advanced Serverboard Setup

Chapter 2: Server Installation2-7Removing the Chassis Top CoverLocate the chassis cover lock (blue lever) at the rear of the chassis cover.1. Slide th

Página 36 - 5-2 Serverboard Installation

2-8SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualFigure 6-3: Installing the Inner Rack Rails Installing the Chassis Handles and Inner RailsI

Página 37 - 5-3 Connecting Cables

Chapter 2: Server Installation2-9Installing the Outer Rails to the RackInstalling the Outer Rails1. Attach the rear bracket to the middle bracket. 2.

Página 38 - 20 19

2-10SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualFigure 6-5: Installing the Rack RailsInstalling the Chassis into a RackInstalling the Chas

Página 39 - Back Panel Connectors

Chapter 2: Server Installation2-112-6 Tower Mounting InstructionsThe SC747 chassis is shipped with the chassis cover and feet pre-installed. To use

Página 40 - Plastic Cap

2-12SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualInstalling Feet on the ChassisInstalling the Chassis FeetPlace the chassis foot in the foo

Página 41

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier

Página 42

3-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual3-2 Control Panel ButtonsThere are two push-buttons located on the front of the chassis. T

Página 43 - 5-6 Installing Memory

Chapter 3: System Interface3-3NIC2:• Indicates network activity on GLAN2 when fl ashing.Overheat/Fan Fail:• When this LED fl ashes it indicates a fa

Página 44 - Memory Support

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Página 45

3-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual3-4 Drive Carrier LEDsYour chassis uses SAS/SATA drives.SAS/SATA DrivesEach SAS/SATA drive

Página 46 - 5-6 Adding PCI Add-On Cards

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Página 47

4-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualThis product may be connected to an IT power system. In all cases, make sure • that the uni

Página 48

Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a

Página 49

4-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual4-4 Operating Precautions!Care must be taken to assure that the chassis cover is in place w

Página 50 - 5-7 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTG-QF serverboard

Página 51

5-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual!UnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static di

Página 52 - 5-8 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Página 53

5-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual1117151614131218191111121101131141151161171181195-4 I/O PortsThe I/O ports are color coded

Página 54

Chapter 5: Advanced Serverboard Setup5-5Back Panel ConnectorsKeyboard (Purple)1. PS/2 Mouse (Green)2. COM Port 1 (Turquoise)3. VGA (Blue) 4. USB 05. U

Página 55 - Chassis Intrusion

SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTG-QF

Página 56

5-6SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual5-5 Installing the Processor and Heatsink!Warning: Avoid placing direct pressure to the to

Página 57

Chapter 5: Advanced Serverboard Setup5-7After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south

Página 58

5-8SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualInstalling the HeatsinkDo not apply any thermal grease to the 1. heatsink or the CPU die; t

Página 59

Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X8DTG-QF supports up to 96 GB of registered ECC or up to 24 GB of unbuf-fered ECC/non-ECC DD

Página 60 - 5-9 Jumper Settings

5-10SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualMemory Population for Optimal Performance-For a motherboard with One CPU (CPU1) installedO

Página 61 - Jumper Settings

Chapter 5: Advanced Serverboard Setup5-11DIMM Module Population Confi gurationFor memory to work properly, follow the tables below for memory installat

Página 62 - USB Wake-Up

5-12SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual5-6 Adding PCI Add-On CardsThe SuperServer 7046GT-TRF can support four PCI-E Gen. 2.0 x16

Página 63 - 5-10 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-13Remove the screw holding the bracket in place and pull the bracket from the 4. chassis.Install your PCI card

Página 64 - 5-11 SATA Ports

5-14SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualInstalling Double-Width Graphics CardsThe SC747 chassis is designed to support up to four

Página 65 - 5-12 Installing Software

Chapter 5: Advanced Serverboard Setup5-15Figure 5-10: Closing the Graphics Card BracketPlace the tabs of the (part number) graphics card bracket into

Página 67

5-16SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualFigure 5-11. X8DTG-QF Layout(not drawn to scale)5-7 Serverboard DetailsNotes:Jumpers not i

Página 68

Chapter 5: Advanced Serverboard Setup5-17X8DTG-QF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-8)JI2C1/JI2C2 SMB to

Página 69 - Advanced Chassis Setup

5-18SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualLED DescriptionDP1 Onboard Standby PWR warning LED IndicatorD33 BMC LED Indicator5-8 Conne

Página 70 - 6-2 Control Panel

Chapter 5: Advanced Serverboard Setup5-19Power Button ConnectorThe PW_ON connector is on pins 1 and 2 of JF1. Momentarily contacting both pins will po

Página 71 - 6-3 System Cooling

5-20SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualNIC2 LEDPin Defi nitions (JF1)Pin# Defi nition 9 Vcc10 GroundNIC2 (JLAN2) LEDThe LED c

Página 72

Chapter 5: Advanced Serverboard Setup5-21Fan HeadersThe X8DTG-QF has ten chassis/system fan headers (Fan1 to Fan10). Fan 7 and Fan 8 are CPU Fans. All

Página 73 - 6-4 Power Supply

5-22SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualLAN1/2 (Ethernet Ports) Two Ethernet ports are located next to the USB 2~5 on the IO Backp

Página 74 - Power Supply Connections

Chapter 5: Advanced Serverboard Setup5-23CD1 Pin Defi nition Pin# Defi nition1 Left2 Ground3 Ground4 Right(Back_Panel) High Defi nition Audio (HD Audio

Página 75 - Tower or Rack Confi guration

5-24SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualInternal BuzzerThe Internal Buzzer, located at SP1, can be used to provide audible alarms

Página 76 - Rotating the Storage Module

Chapter 5: Advanced Serverboard Setup5-25Overheat LED/Fan Fail (JOH1)The JOH1 header is used to connect an LED indicator to provide warnings of chas-s

Página 77

viSUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Página 78 - Removing a Drive Carrier

5-26SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpe

Página 79

Chapter 5: Advanced Serverboard Setup5-27LAN1/2 Enable/Disable Change the setting of jumper JPL1/JPL2 to enable or disable the LAN1/LAN2 Ethernet port

Página 80 - Adding Peripheral Drives

5-28SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualFP USB Wake-up En-able (JPUSB2) Jumper SettingsPin# Defi nition1-2 Enabled2-3 Disabled

Página 81

Chapter 5: Advanced Serverboard Setup5-29GLAN LEDsThere are two GLAN ports on the mother-board. An additional IPMI dedicated LAN port is also located

Página 82

5-30SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual5-11 SATA PortsSerial ATAPin Defi nitions Pin# Defi nition1 Ground2 TX_P3 TX_N4 Ground5 R

Página 83 - Chapter 7

Chapter 5: Advanced Serverboard Setup5-315-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system

Página 84 - 7-2 Main Setup

5-32SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports

Página 85

Chapter 5: Advanced Serverboard Setup5-33Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S

Página 86 - XBoot Features

5-34SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualNotes

Página 87 - Processor and Clock Options

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Página 88

viiTable of ContentsChapter 3 System Interface3-1 Overview ...

Página 89

6-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual6-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents

Página 90 - XQPI and IMC Confi guration

Chapter 6: Advanced Chassis Setup6-3The control panel LEDs inform you of system status. See "Chapter 3: System In-terface" for details on th

Página 91

6-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualRear Fan Release TabFigure 6-4: Rear System Chassis FansFigure 6-3: Mid-System Chassis Fans

Página 92

Chapter 6: Advanced Chassis Setup6-56-4 Power SupplyThe SC747 chassis has a 1400W (redundant) power supply. This power supply is auto-switching capabl

Página 93 - Route Port 80h Cycles to

6-6SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualPower Supply Cables Name Qty Connects to: Description20-pin or 24-pin power cable1 Motherbo

Página 94 - IDE/SATA/Floppy Confi guration

Chapter 6: Advanced Chassis Setup6-76-5 Confi guring the the Storage Module This section covers confi guring the storage module in the SC747 chassis.Sto

Página 95

6-8SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualRotating the Storage Module for Rack MountingOpen the chassis cover.1. Locate the storage m

Página 96

Chapter 6: Advanced Chassis Setup6-9Figure 6-9: Chassis Storage ModuleTurn the storage module 90 degrees (as illustrated).5. Reinsert the module into

Página 97 - XPCI/PnP Confi guration

6-10SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualRemoving a Drive CarrierUse the procedure below to add hard drives to the drive carriers.A

Página 98 - XRemote Access Confi guration

Chapter 6: Advanced Chassis Setup6-11Hard DriveHard Drive TrayFigure 6-11: Adding a Hard Drive to the Drive CarrierPlace the hard drive to the hard dr

Página 99 - Hardware Health Confi guration

viiiSUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualChapter 6 Advanced Chassis Setup6-1 Static-Sensitive Devices ...

Página 100

6-12SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualAdding Peripheral DrivesYou can add up to three peripheral drives (DVD-ROM, CD-ROM, fl oppy

Página 101

Chapter 6: Advanced Chassis Setup6-136-6 Installing Hard Drives in the ChassisChassis hard drives are mounted in drive carriers to simplify their ins

Página 102 - XACPI Confi guration

6-14SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualFigure 6-15: Removing a Dummy Drive TrayInsert the hard drive into the chassis. To do this

Página 103

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTG-QF. The AMI ROM BIOS is stored in a F

Página 104 - View BMC System Event Log

7-2SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is t

Página 105 - Subnet Mask Confi guration

Chapter 7: BIOS7-3Supermicro X8DTG-QFBIOS Build Version: This item displays the BIOS revision used in your sys-• tem.BIOS Build Date: This item displa

Página 106 - MAC Address Confi guration

7-4SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select the Boot Setup submenu, and

Página 107 - 7-4 Security Settings

Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The optio

Página 108

7-6SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualRatio CMOS SettingThis option allows the user to set the ratio between the CPU Core Clock a

Página 109 - 7-5 Boot Confi guration

Chapter 7: BIOS7-7Execute-Disable Bit Capability (Available when supported by the OS and the CPU)Set to Enabled to enable the Execute Disable Bit whic

Página 110 - 7-6 Exit Options

Chapter 1 Introduction1-1 OverviewThe SuperServer 7046GT-TRF/7046GT-TRF-TC4 is a supercomputing server that is comprised of two main subsystems: the S

Página 111 - Load Fail-Safe Defaults

7-8SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualC3 Auto DemotionWhen enabled, the CPU will conditionally demote C6 or C7 requests to C3 bas

Página 112

Chapter 7: BIOS7-9Memory FrequencyThis feature forces a DDR3 frequency slower than what the system has detected to run at the frequency as specifi ed.

Página 113 - BIOS Error Beep Codes

7-10SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualInlet TemperatureThis is the temperature detected at the chassis inlet. Each step is in 0.

Página 114

Chapter 7: BIOS7-11NUMA SupportSelect Enabled to effi ciently execute applications under Non-Uniform Memory Ar-chitecture (NUMA)-aware Operating System

Página 115 - Installing Windows

7-12SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualXIDE/SATA/Floppy Confi gurationWhen this submenu is selected, the AMI BIOS automatically de

Página 116

Chapter 7: BIOS7-13LBA/Large ModeLBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive cap

Página 117 - System Specifi cations

7-14SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualDMA ModeSelect Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE di

Página 118

Chapter 7: BIOS7-1532Bit Data TransferSelect Enable to enable 32-bit IDE data transferring support. The options are Enabled and Disabled.XPCI/PnP Confi

Página 119 - Regulatory Compliance

7-16SUPERSERVER 7046GT-TRF/7046GT-TRF-TC4 User's ManualLoad Onboard LAN 1 Option ROM/Load Onboard LAN 2 Option ROM Select Enabled to enable onbo

Página 120

Chapter 7: BIOS7-17Flow ControlThis feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and Softw

Comentários a estes Manuais

Sem comentários