SUPERSUPERSERVER 6016T-MTHFSUPERSERVER 6016T-MTLFUSER’S MANUALRevision 1.0a®
NotesxSUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual
B-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used
Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-MTHF/6016T-MTLF is comprised of two main subsystems: the SC813MTQ-600C/SC813MTQ-350C 1U chassi
1-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 6016T-MTHF/6016T-MTLF lies the X8DTL-iF
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MTQ chassis.System PowerWhen
1-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualFigure 1-1. Intel 5500 Chipset: System Block Diagram Note: This is a general block diagram. Ple
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6016T-
2-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipme
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual2-4 Installing the System into a RackThis section provides information on installing the Super
Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 6016T-MTHF/6016T-MTLF in the rack (see Rac
2-6SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a Te
2-8SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual2-5 Checking the Motherboard SetupAfter you install the 6016T-MTHF/6016T-MTLF in the rack, you
Chapter 2: Server Installation2-9Figure 2-4.Accessing the Inside of the SuperServer 6016T-MTHF/6016T-MTLF2-6 Checking the Drive Bay SetupNext, you sh
2-10SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualAlso note that all power and data cables have been routed in such a way that 2. they do not bl
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca
3-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTQ chassis has fi ve
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when t
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTL-iF serverboard
5-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-char
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual5-4 Rear I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation.
Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a gene
5-6SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the n
Chapter 5: Advanced Serverboard Setup5-7Screw#1Screw#1Screw#2Screw#2Install Screw#1Notes: The serverboard comes with a heatsink bracket pre-in-stalled
5-8SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualRemoving the HeatsinkWarning: We do not recommend that the CPU or the heatsink be re-moved. How
Chapter 5: Advanced Serverboard Setup5-95-6 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.CAUTIONExerci
5-10SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualPopulating DIMMs for Optimal PerformanceFor One CPU (CPU1) Installed (Populate the CPU1 DIMM s
Chapter 5: Advanced Serverboard Setup5-115-7 Adding PCI CardsThe 6016T-MTHF/6016T-MTLF includes a CSE-RR1U-E16 riser card. This riser fi ts into a PCI
5-12SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualFigure 5-4. X8DTL-iF LayoutJumpers not indicated are for test purposes only. A square contact
Chapter 5: Advanced Serverboard Setup5-13X8DTL-iF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear Open (Normal)JI2C1/JI2C2 SMB to PCI
5-14SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset
Chapter 5: Advanced Serverboard Setup5-15Overheat LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning of c
vPrefaceNotes
5-16SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualChassis IntrusionThe Chassis Intrusion header is des-ignated JL1. See the board layout for the
Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL on the serverboard. See the table on the right for pin
5-18SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualSGPIO HeadersTwo SGPIO (Serial General Purpose Input/Output) headers are included on the serve
Chapter 5: Advanced Serverboard Setup5-19LAN1/2 (Ethernet Ports)Two gigabit Ethernet ports (desig-nated LAN1 and LAN2) are located beside the VGA port
5-20SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers
Chapter 5: Advanced Serverboard Setup5-21Watch DogJWD enables the Watch Dog function, a system monitor that takes action when a software application f
5-22SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual5-11 Onboard IndicatorsLAN Port LEDsThe LAN1/2 Ethernet ports (located beside the VGA port) an
Chapter 5: Advanced Serverboard Setup5-235-12 SATA PortsSATA PortsThere are no jumpers to en-able the SATA ports, which are designated I-SATA0 ~ I-SAT
5-24SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the op
Chapter 5: Advanced Serverboard Setup5-25Supero Doctor IIIThe Supero Doctor III program is a Web based management tool that supports remote management
viSUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualTable of ContentsPrefaceAbout This Manual ...
5-26SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicr
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the c
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance fans provide the cooling for the SuperServer 6016T-MTHF/6016T-MTLF. The
6-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualUse caution when working around the SATA backplane. Do not touch the backplane with any metal o
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Drive in a CarrierSATA BackplaneThe SATA drives plug into a backplane that provides power,
6-6SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to th
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6016T-MTHF has a single 600 watt power supply and the SuperServer 6016T-MTLF has a
6-8SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualNotes
Chapter 7: AMI BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTL-iF motherboard. The AMI ROM BIOS
viiTable of ContentsInstalling the Rack Rails ... 2-5Installing the Serv
7-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the m
Chapter 7: AMI BIOS7-3Supermicro X8DTL-3/i/3F/iFVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays
7-4SUPERSERVER 6016T-MTHF/6016T-MTLF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter>
Chapter 7: AMI BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the <F1> key is pressed if an error occurs. The optio
7-6SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualRTD Alarm Time (Available if Resume on RTC Alarm is Enabled)Set the time when the system wakes
Chapter 7: AMI BIOS7-7and Disabled. Note: If there is any change to this setting, you will need to power off and restart the system for the change to
7-8SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualC1 Auto DemotionWhen this feature is enabled, the CPU will conditionally demote C3, C6 or C7 re
Chapter 7: AMI BIOS7-9QPI FrequencyThis selects the desired QPI frequency. The options are Auto, 4.800 GT, 5.866GT, 6.400 GT.QPI L0s and L1This enable
7-10SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualGuardband Temperature (Closed Loop only)This is the temperature applied to the DIMM temperatur
Chapter 7: AMI BIOS7-11NUMA SupportSelect Enabled to enable Non-Uniform Memory Access support in order to improve CPU performance. The options are Ena
viiiSUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualMemory Support ...
7-12SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualConfi gure SATA#1 asThis feature allows the user to select the drive type for SATA#1. The optio
Chapter 7: AMI BIOS7-13Block (Multi-Sector Transfer)Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512
7-14SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualSelect MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 1
Chapter 7: AMI BIOS7-15PCI Latency TimerThis feature sets the latency Timer for each PCI device installed on a PCI bus. Select 64 to set the PCI laten
7-16SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualXRemote Access Confi guration Remote Access This allows the user to enable the Remote Access fe
Chapter 7: AMI BIOS7-17XHardware Health MonitorThis feature allows the user to monitor system health and review the status of each item as displayed.C
7-18SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualThe motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust
Chapter 7: AMI BIOS7-19Select Workstation if your system is used as a Workstation. Select Server if your system is used as a Server. Select Disabled
7-20SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualACPI Version FeaturesUse this feature to select the appropriate ACPI Version for your system t
Chapter 7: AMI BIOS7-21Event Dir Type• Event Data.• Clear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log.
Table of ContentsixWatch Dog ... 5-21I2C Bus to PCI/PCI-E
7-22SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualMac Address The BIOS will automatically enter the Mac address of this machine; however it may
Chapter 7: AMI BIOS7-23Supervisor Password This item indicates if a Supervisor password has been entered for the system. "Not Installed" mea
7-24SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualPassword CheckThis item allows you to check a password after it has been entered. The options
Chapter 7: AMI BIOS7-25XRemovable DrivesThis feature allows the user to specify the boot sequence from available Removable Drives. The settings are 1s
7-26SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualDiscard ChangesSelect this option to discard all the changes and return to the Setup Utility.
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Post Error Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Two Intel® 5600/5500 Series processors in LGA1366 sockets No
B-2SUPERSERVER 6016T-MTHF/6016T-MTLF User's ManualWeight Gross Weight: 38 lbs. (17.3 kg.)System Cooling Four 4-cm high performance f
B-3Appendix B: System Specifi cationsNotes