Supermicro SYS-5026TI-HTRF Manual do Utilizador Página 69

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 104
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 68
Chapter 6: Advanced Chassis Setup
6-7
6-5 Node Installation/Removal
As with any server system, power must be removed from the serverboard when
upgrading or installing memory or processors. In the 2U Twin
2
server, the server-
boards (nodes) are capable of being hot-swapped from the chassis, allowing one
to be powered down for servicing while the other continues operating.
Important! Removing a node from the server affects the air ow
throughout the system. For this reason, nodes should be removed,
serviced and replaced as quickly as possible. Also note that powering
down a node will power down all the hard drives that are logically
associated with it.
!
Removing a Node
Depress the power button on the control panel to power down the node.1.
There are two latches located below the handles at the rear of the node tray. 2.
Push both of these inward.
While pushing the latches inward, grasp both handles and pull the node from 3.
the chassis.
Perform any service needed to the node in a timely manner.4.
Reinstall the node by pushing it into its bay until rmly seated.5.