D-6
SC213 Chassis Manaual
Socket Settings
Socket Socket Setting Note
REMOTE_FAN_FAIL_
SOCKET1
Connected
Front Panel Fan Fail indicator
(Optional)
General Jumper Settings
Jumper Jumper Settings Note
PRI_MODE1 1-2
Factory Setting
Do not change
BUZZER_ENB1
Open: Disable
Closed: Enable
Buzzer Enable*
Front Panel LEDs
LED State Specication
12V_LED1 OFF
Backplane power failure. Light is on during
normal operation.
5V_LED1 OFF
Backplane power failure. Light is on during
normal operation.
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
Hard drive failure1.
Fan failure2.
System temperature over 45º Celsius.3.