6-3
Safety Information and Technical Speci cations
Understanding Virtual Disk Parameters
This section describes the Virtual Disk Parameters that you can set when you
use the Guided Con guration or Manual Con guration modes of the Con guration
Wizard. You should change these parameters only if you have a speci c reason for
doing so. It is usually best to leave them at their default settings.
Stripe Size: A stripe size of 64 Kbytes is supported.
Disk Cache Policy: Select a cache setting for this disk: Unchanged, Enabled,
or Disabled.
Init State
No Initialization: The new con guration is not initialized and the existing data on
the disks is not overwritten.
Fast Initialization: MegaRAID Storage Manager software quickly writes zeroes
to the rst and last 8 Mbyte regions of the new virtual disk.
Full Initialization: A complete initialization is done on the new con guration. This
may take a long time if the disks are large.